Set the lift settings
Configures panel floor number and lift call actions.
The function works when using the appropriate lift module, for example EVRC-IP. For the detailed description please follow lift module manual.
- The DTMF value for elevator calling and lock opening cannot be the same
- application/json
Request Body required
- floor_number integer requiredPossible values: >= 1and<= 98Default value: 12The model describes the number of the floor on which the panel is installed for identification by the elevator module 
- send_identifier_number booleanManages sending the ID number to the elevator controller 
- get_apartment_identifier_from_call booleanAllows to send to the elevator the first linked to apartment identifier upon lock opening in call 
- call_when object required- type of event on which to call elevator - monitor_opens_lock object required- when lock is opened from the monitor is_enabled boolean required- describes feature status, true - on / false - off - user_opens_lock object required- when lock is opened by user is_enabled boolean required- describes feature status, true - on / false - off - monitor_call_in_talk object required- during call is_enabled boolean required- describes feature status, true - on / false - off dtmf_code string required- Possible values: Value must match regular expression - ^[\d*#ABCD]{1,4}$- Default value: - DC- dtmf code that is sent to trigger elevator 
- 200
- 400
- 401
OK
Validation error. Required fields are not provided.
- Wrong floor number
- Missed json body or wrong param. Response sample:
  "error": "Wrong JSON body"
- Required field is not provided. Response sample:
  "error": "Wrong JSON body: no value for `param`"
where param - is a required field that was not provided
- Field was of the wrong type. Response sample:
  "error": "Wrong JSON body: value `param` was of the wrong type"
where param - is a field of the wrong type
wrong
- application/json
- Schema
- Example (from schema)
- Base
- No value
- Wrong param type
- Wrong floor number
- D T M F code already in use
Schema
- error stringerror type/info 
{
  "error": true
}
{
  "error": "Wrong JSON body"
}
{
  "error": "Wrong JSON body: no value for `param`"
}
{
  "error": "Wrong JSON body: value `param` was of the wrong type"
}
{
  "error": "Wrong floor number"
}
{
  "error": "Wrong JSON body: value dtmf_code was wrong. (This dtmf code is already used for lock 1)"
}
Unauthorized request. Log In
- application/json
- Schema
- Example (from schema)
- Log In
Schema
- error stringerror message 
{
  "error": "Log In"
}
{
  "error": "Log In"
}