Set remote access server settings
Set remote access server settings.
If enabled - panel sends request to remote server and waits for response 10 s. If server doesn't respond during timeout panels takes access control itself. If custom server not specified request will be send to Link
.
- Device sends post request with application/json body:
{
"identifier_number": "5a4sd7a5s4d5as3d54asd",
"identifier_type": "card"
}
identifier_type can have three types: 'card', 'input_code' and 'qr'
- Device waits for response with next application/json bodies:
Access not handled. Panel should handle access itself:
{
"handled": false
}Access not granted:
{
"handled": true,
"access": {
"granted": false
}
}Access granted, open first lock:
{
"handled": true,
"access": {
"granted": true,
"lock_number": 1
}
}- where 'lock_number' (lock to open) may take next values:
- 0 - both locks (1 and 2..8 if used SH-42 module)
- 1..8 - indexes available for the lock number
- also, you can use
GET /access/general/lock/open/remote/accepted/{lockNumber}
to open specific lock
- where 'lock_number' (lock to open) may take next values:
- application/json
Request Body required
- MOD1
- MOD2
- enabled boolean required
describes feature status, true - on / false - off
- custom_server_enabled boolean required
If disabled panel will use link server remote control api
- enabled boolean required
describes feature status, true - on / false - off
- custom_server_enabled boolean required
If disabled panel will use link server remote control api
- custom_server_api_url string required
Custom server api url for sending logs
anyOf
Responses
- 200
- 401
OK
Unauthorized request. Log In
- application/json
- Schema
- Example (from schema)
- Log In
Schema
- error string
error message
{
"error": "Log In"
}
{
"error": "Log In"
}
Loading...