Skip to main content

Set security zones settings

Set security zones settings. Available only on the master device.

Request Body required
  • zones object[]

    Possible values: <= 8

  • zone_id integer required

    Possible values: >= 1 and <= 8

    ID of zone

  • type string required

    Possible values: [normal, emergency, 24_hour]

    Zone type. Normal - work only if enabled in scene, 24 and emergency will work all the time

  • mode string required

    Possible values: [, no, nc, bell, call]

    Dry contacts mode. 3c - trigger, no - normal open, nc - normal closed, bell - doorbell mode

  • delay integer required

    Possible values: [0, 5, 15, 20, 25, 40, 60]

    Delay for sensor activation in seconds

  • sensor string required

    Possible values: [smoke, gas, pir, door, window, panic, flood, pull_cord, bed_mat]

    Sensor type

Responses

OK

Loading...