Set device settings

Set device settings

Request Body
  • device_mode string required

    Possible values: [access-control-manual, call-any, call-up, call-down, call-up-down]

    Default value: call-any

    ModeAvailable portsDescription
    access-control-manual16Module duplicates the floor buttons in the lift car and allows them to be activated when using identifiers (RFID, QR etc.)
    call-any16Mode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the UP or DOWN buttons contacts on the floor or device that replaces them.
    Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
    Also allows:
  • Call lift to the panel floor when using identifier with panel
  • Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
  • call-up16Mode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the UP buttons contacts on the floor or device that replaces them. Reacts on incoming "Appoint" broadcast - the lift will arrive at the monitor installation floor when UP button is pressed.
    Also allows if handle_permit_in_updown_mode enabled:
  • Call lift to the panel floor when using identifier with panel
  • Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
  • Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
  • call-down16Mode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the DOWN buttons contacts on the floor or device that replaces them. Reacts on incoming "Appoint" broadcast - the lift will arrive at the monitor installation floor when DOWN button is pressed.
    Also allows if handle_permit_in_updown_mode enabled:
  • Call lift to the panel floor when using identifier with panel
  • Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
  • Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
  • call-up-down8 up, 8 downMode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the UP and DOWN buttons contacts on the floor or device that replaces them. Reacts on incoming "Appoint" broadcast - the lift will arrive at the monitor installation floor when UP or DOWN button is pressed.
    Relays 1-8 are connected to the lift call DOWN buttons.
    Relays 9-16 are connected to the lift call UP buttons.
    Also allows if handle_permit_in_updown_mode enabled:
  • Call lift to the panel floor when using identifier with panel
  • Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
  • Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
  • relay_mode string required

    Possible values: [COM-NO, COM-NC]

  • invert_all_relays boolean required

    Default value: false

    turning on all relays after booting

  • relay_open_time integer required

    Possible values: >= 10 and <= 9999

    Relay switching time, in milliseconds

  • handle_permit_in_updown_mode boolean

    Default value: false

    Allows broadcasts processing in UP, DOWN, and UP-DOWN modes. Feature allows:

    • Call lift to the panel floor when using identifier with panel
    • Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
    • Reacts on incoming Permit broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed. In UP-DOWN mode Permit will trigger only UP relays.
  • lift_release_time object required
  • api integer required

    Possible values: >= 1 and <= 9999

    Relay switching time via API, in seconds

  • card integer required

    Possible values: >= 1 and <= 9999

    Relay switching time via identifiers, in seconds