Set device settings
Set device settings
- application/json
Request Body
- device_mode string required
Possible values: [
access-control-manual
,call-any
,call-up
,call-down
,call-up-down
]Default value:
call-any
Mode Available ports Description access-control-manual 16 Module duplicates the floor buttons in the lift car and allows them to be activated when using identifiers (RFID, QR etc.) call-any 16 Mode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the UP or DOWN buttons contacts on the floor or device that replaces them.
Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
Also allows:- Call lift to the panel floor when using identifier with panel
- Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
call-up 16 Mode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the UP buttons contacts on the floor or device that replaces them. Reacts on incoming "Appoint" broadcast - the lift will arrive at the monitor installation floor when UP button is pressed.
Also allows if handle_permit_in_updown_mode enabled:- Call lift to the panel floor when using identifier with panel
- Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
- Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
call-down 16 Mode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the DOWN buttons contacts on the floor or device that replaces them. Reacts on incoming "Appoint" broadcast - the lift will arrive at the monitor installation floor when DOWN button is pressed.
Also allows if handle_permit_in_updown_mode enabled:- Call lift to the panel floor when using identifier with panel
- Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
- Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
call-up-down 8 up, 8 down Mode duplicates the functionality of the lift call buttons on the floor, the relay contacts are connected to the UP and DOWN buttons contacts on the floor or device that replaces them. Reacts on incoming "Appoint" broadcast - the lift will arrive at the monitor installation floor when UP or DOWN button is pressed.
Relays 1-8 are connected to the lift call DOWN buttons.
Relays 9-16 are connected to the lift call UP buttons.
Also allows if handle_permit_in_updown_mode enabled:- Call lift to the panel floor when using identifier with panel
- Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
- Reacts on incoming "Permit" broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed.
- relay_mode string required
Possible values: [
COM-NO
,COM-NC
] - invert_all_relays boolean required
Default value:
false
turning on all relays after booting
- relay_open_time integer required
Possible values:
>= 10
and<= 9999
Relay switching time, in milliseconds
- handle_permit_in_updown_mode boolean
Default value:
false
Allows broadcasts processing in UP, DOWN, and UP-DOWN modes. Feature allows:
- Call lift to the panel floor when using identifier with panel
- Call lift to the panel floor when the lock is opened during a call between the panel and the monitor
- Reacts on incoming
Permit
broadcast - the lift will arrive at the monitor installation floor when Permit button is pressed. In UP-DOWN modePermit
will trigger only UP relays.
lift_release_time object required
api integer requiredPossible values:
>= 1
and<= 9999
Relay switching time via API, in seconds
card integer requiredPossible values:
>= 1
and<= 9999
Relay switching time via identifiers, in seconds
- 200
- 400
- 401
OK
Data validation error
- application/json
- Schema
- Example (from schema)
Schema
error object
code stringPossible values: [
invalid_authentification
,permission_denied
,not_valid
,system_error
]Error code
message stringError message
data object
Did not pass validation parameters. Can be represented as an object, which can include field names, arrays, query parameters etc.
param string
{
"error": {
"code": "not_valid",
"message": "Data validation error",
"data": {
"param": "must be an string"
}
}
}
Please log in
- application/json
- Schema
- Example (from schema)
- Example
Schema
error object
code stringPossible values: [
invalid_authentification
,permission_denied
,not_valid
,system_error
]Error code
message stringError message
data object
Did not pass validation parameters. Can be represented as an object, which can include field names, arrays, query parameters etc.
param string
{
"error": {
"code": "not_valid",
"message": "Data validation error",
"data": {
"param": "must be an string"
}
}
}
{
"error": {
"code": "invalid_authentification",
"message": "Log In"
}
}