Skip to main content

Set NowIP settings

Configures the NowIP alarm notification settings.

NowIP provides additional alerts when a security alarm is triggered on the monitor. Notifications are sent as SIP messages to the configured SIP numbers where the BAS-IP Intercom app is installed.

Request Body
  • now_ip object

    NowIP settings

  • enable boolean

    Determines whether the feature is enabled

  • main_number string

    First SIP number used to notify about triggers

  • second_number string

    Second SIP number used to notify about triggers

  • second_number_delay_call integer

    Delay between first and second SIP numbers call in seconds

  • auto_call object

    Determines whether automatics SIP call is enabled when alarm activated

  • enable boolean

    Determines whether the feature is enabled

  • number string

    A call will be made to this SIP number after the sensor is triggered

  • heartbeat object

    Enable SIP messages periodic notifications about alarm status

  • enable boolean

    Determines whether the feature is enabled

  • data string

    Message content

  • timeout integer

    SIP message interval in seconds

  • zones object[]

    List of messages that will be sent in a SIP message when proper sensor is triggered

  • zone_id integer

    Possible values: <= 15

    Zone number

  • zone_name string

    Zone name

Responses