Set NowIP settings

Configures NowIP settings.

They provides additional alert on alarm triggering on the internal monitor using the SIP protocol. Notification occurs by sending SIP messages to the specified SIP number on which the BAS-IP Intercom application is installed.

Request Body
  • now_ip object

    NowIP settings

  • enable boolean

    Determines whether the feature is enabled

  • main_number string

    First SIP number used to notify about triggers

  • second_number string

    Second SIP number used to notify about triggers

  • second_number_delay_call integer

    Delay between first and second SIP numbers call in seconds

  • auto_call object

    Determines whether automatics SIP call is enabled when alarm activated

  • enable boolean

    Determines whether the feature is enabled

  • number string

    A call will be made to this SIP number after the sensor is triggered

  • heartbeat object

    Enable SIP messages periodic notifications about alarm status

  • enable boolean

    Determines whether the feature is enabled

  • data string

    Message content

  • timeout integer

    SIP message interval in seconds

  • zones object[]

    List of messages that will be sent in a SIP message when proper sensor is triggered

  • zone_id integer

    Possible values: <= 15

    Zone number

  • zone_name string

    Zone name

Responses