Skip to main content

Get remote access server settings

Get remote access server settings.

If enabled - panel sends request to remote server and waits for response 10 s. If server doesn't respond during timeout panels takes access control itself. If custom server not specified request will be send to Link.

  1. Device sends post request with application/json body:
{
"identifier_number": "5a4sd7a5s4d5as3d54asd",
"identifier_type": "card"
}

identifier_type can have three types: 'card', 'input_code' and 'qr'

  1. Device waits for response with next application/json bodies:
  • Access not handled. Panel should handle access itself:

    {
    "handled": false
    }
  • Access not granted:

    {
    "handled": true,
    "access": {
    "granted": false
    }
    }
  • Access granted, open first lock:

    {
    "handled": true,
    "access": {
    "granted": true,
    "lock_number": 1
    }
    }
    • where 'lock_number' (lock to open) may take next values:
      • 0 - both locks (1 and 2..8 if used SH-42 module)
      • 1..8 - indexes available for the lock number
    • also, you can use GET /access/general/lock/open/remote/accepted/{lockNumber} to open specific lock
Responses

OK


Schema
  • enabled boolean
  • custom_server_enabled boolean

    Default value: false

  • custom_server_api_url string
Loading...