Get management server settings
Get management server settings.
If Link is enabled - server will sync identifiers, access rules, logs etc.
If realtime logging is enabled - panel will send the logs in realtime to the server.
If heartbeat is enabled - panel will send keep alive to the server every 10 seconds. When MQTT protocol is used heartbeat is enabled by default.
Responses
- 200
 - 401
 
OK
- application/json
 
- Schema
 - Example (from schema)
 - Mqtt
 - Htpp
 
Schema
- is_enabled boolean
 - protocol string
Possible values: [
http,mqtt] settings object
oneOf- MOD1
 - MOD2
 
url ipv4 or dnsServer address
password stringis_logging_enabled booleanis_encrypted booleanIf enabled you can provide custom sertificate with
POST /network/management/settings/certificateor device will use default one.url ipv4 or dnsServer address
password stringis_logging_enabled booleanis_heartbeat_enabled booleanIf enabled device will send keep alive request every 10 seconds
{
  "is_enabled": true,
  "protocol": "http",
  "settings": {
    "url": "link.bas-ip.com",
    "password": "123abc",
    "is_logging_enabled": false,
    "is_encrypted": false
  }
}
{
  "is_enabled": false,
  "protocol": "mqtt",
  "settings": {
    "url": "link.bas-ip.com",
    "password": "123abc",
    "is_logging_enabled": true,
    "is_encrypted": true
  }
}
{
  "is_enabled": false,
  "protocol": "http",
  "settings": {
    "url": "link.bas-ip.com",
    "password": "123abc",
    "is_logging_enabled": true,
    "is_heartbeat_enabled": true
  }
}
Unauthorized request. Log In
- application/json
 
- Schema
 - Example (from schema)
 - Log In
 
Schema
- error string
 
{
  "error": "Log In"
}
{
  "error": "Log In"
}